Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2021, 11:34 AM
  • H 0265_H 0264_04122021_045230.mp4

Date
04/12/2021
W/O
887702
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00173
PipeID
P10717
Time
4:34 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8826
Sewer Name
H JOINT OUTFALL H - UNIT 2H
City
VERNON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 23
Page No.
02
Purpose
Routine Assessment
Project
CA_WO_887702
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
H 0265
Downstream MH
H 0264
Dir. of Survey
Downstream
Length Surveyed
268 ft.
Total Length
268 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
7
Pipe schematic from manhole H 0265 to H 0264
MH: H 0265MH: H 0264downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 026512.3 ft. CS - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES69.2 ft. CS - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES85.4 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES101 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"118.4 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"176.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8" - ANBANDONED268 ft. AMH - Downstream Manhole, Survey Ends - H 0264

Observation photos (4)

  • Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

    12.3 ft. - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    69.2 ft. - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    85.4 ft. - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

    118.4 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

Observations (10)

DistanceCodeObservation
268AMHH 0264
0MWL
69.2CS
176.8TFANBANDONED
118.4TB
0MWM
101TFC
85.4CM
12.3CS
0AMHH 0265

Properties (6)

custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2021-04-12T04:34:11-07:00
documentation
PRO PIPE
is_lateral_inspection
false