- Date
- 04/12/2021
- W/O
- 885817
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00134
- PipeID
- P09762
- Time
- 1:41 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8726
- Sewer Name
- C JOINT OUTFALL C - UNIT 6E
- City
- CERRITOS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- RFIR_WO_885817_TV19035_APR2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- C 0302
- Downstream MH
- C 0301
- Dir. of Survey
- Downstream
- Length Surveyed
- 535.6 ft.
- Total Length
- 535.6 ft.
- Structural Index
- 2
- Structural Quick
- 2T00
- Structural Rating
- 212
- O&M Index
- 3
- O&M Quick
- 3Q21
- O&M Rating
- 278
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 490
Pipe schematic from manhole C 0302 to C 0301 Observation photos (2)

74.5 ft. - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: NO, Start - SLUDGE

500.6 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 12 to 05 o'clock, , within 8 inches of joint: NO