Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2021, 09:31 AM
  • C 0301_C 0300_04122021_024039.mp4

Date
04/12/2021
W/O
885817
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00134
PipeID
P09761
Time
2:31 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8726
Sewer Name
C JOINT OUTFALL C - UNIT 6E
City
CERRITOS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_885817_TV19035_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
C 0301
Downstream MH
C 0300
Dir. of Survey
Downstream
Length Surveyed
201 ft.
Total Length
201 ft.
Structural Index
2
Structural Quick
2G00
Structural Rating
78
O&M Index
3
O&M Quick
3300
O&M Rating
9
Overall Index
2
Overall Quick
Overall Rating
87
Pipe schematic from manhole C 0301 to C 0300
MH: C 0301MH: C 0300downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 03012.4 ft. MGO - General Observation - MAG COAT2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.5 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 07 to 10 o'clock, , within 8 inches of joint: NO33.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"33.3 ft. ID - Infiltration Dripper, at 08 o'clock, within 8 inches of joint: NO41.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"78 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: NO81.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"89.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"129.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"137.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"178 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"186.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"198 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish201 ft. AMH - Downstream Manhole, Survey Ends - C 0300201 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (3)

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 07 to 10 o'clock,  , within 8 inches of joint: NO

    32.5 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 07 to 10 o'clock, , within 8 inches of joint: NO

  • Infiltration Dripper, at 08 o'clock, within 8 inches of joint: NO

    33.3 ft. - Infiltration Dripper, at 08 o'clock, within 8 inches of joint: NO

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: NO

    78 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: NO

Observations (19)

DistanceCodeObservation
137.6TFC
33.3TFC
33.3ID
41.3TFC
201AMHC 0300
129.7TFC
186.2TFC
201MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
0MWL
78ID
89.6TFC
2.4MGOMAG COAT
81.5TFC
178TFC
2.5SSS
0AMHC 0301
32.5DAE
198SSS

Properties (7)

additional_info
630074041221001
custom_field_three
INFILTRATION
custom_field_two
3
customer
1
datetime
2021-04-12T02:31:46-07:00
documentation
PROPIPE
is_lateral_inspection
false