Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2021, 07:57 AM
  • C 0298_C 0297_04132021_010404.mp4

Date
04/12/2021
W/O
885817
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00134
PipeID
P09758
Time
12:57 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8727
Sewer Name
C JOINT OUTFALL C - UNIT 6E
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_885817_TV19035_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
27 in.
Upstream MH
C 0297
Downstream MH
C 0298
Dir. of Survey
Upstream
Length Surveyed
131.7 ft.
Total Length
131.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2C00
O&M Rating
36
Overall Index
2
Overall Quick
Overall Rating
36
Pipe schematic from manhole C 0297 to C 0298
MH: C 0297MH: C 0298upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO, Finish0 ft. AMH - Upstream Manhole, Survey Ends - C 029824 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"31.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"83.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"89.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO, Start91.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"129.4 ft. MGO - General Observation - MAG COAT131.7 ft. MWM - Water Mark, 25 %of cross sectional area131.7 ft. AMH - Downstream Manhole, Survey Begins - C 0297131.7 ft. MWL - Water Level, 15 %of cross sectional area131.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (1)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: NO, Start

    42.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO, Start

Observations (14)

DistanceCodeObservation
48.4TFC
40.2TFC
107.7TFC
0MWM
2.3MGOMAG COAT
131.7MGOCONNECTION AT THE MH 3 OC'LOCK
131.7DAE
0AMHC 0297
99.8TF
0MWL
42.3DAE
131.7AMHC 0298
0MGOCONNECTION AT THE MH 9 OC'LOCK
8.2TFC

Properties (7)

additional_info
630074041221201
custom_field_three
ENCRUSTATION
custom_field_two
3
customer
1
datetime
2021-04-12T00:57:00-07:00
documentation
PROPIPE
is_lateral_inspection
false