Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2021, 07:22 AM
  • C 0292_C 0291_04132021_003635.mp4

Date
04/13/2021
W/O
885817
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00134
PipeID
P09752
Time
12:22 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8727
Sewer Name
C JOINT OUTFALL C - UNIT 6E
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_885817_TV19035_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
30 in.
Upstream MH
C 0292
Downstream MH
C 0291
Dir. of Survey
Downstream
Length Surveyed
190.8 ft.
Total Length
190.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole C 0292 to C 0291
MH: C 0292MH: C 0291downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - C 02920 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 15 %of cross sectional area2.6 ft. MGO - General Observation - MAG COAT40.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"48.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"88.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"96.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"125.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 10 o'clock, , within 8 inches of joint: YES137 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"144.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"190.8 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED190.8 ft. AMH - Downstream Manhole, Survey Ends - C 0291

Observation photos (1)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 10 o'clock,  , within 8 inches of joint: YES

    125.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 10 o'clock, , within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
0MWM
137TFC
2.6MGOMAG COAT
48.5TFC
0MGOCONNECTION AT THE MH 9 OC'LOCK
0AMHC 0292
40.5TFC
0MGOCONNECTION AT THE MH 3 OC'LOCK
190.8MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
96.8TFC
0MWL
190.8AMHC 0291
144.7TFC
125.4DAE
88.7TFC

Properties (7)

additional_info
630074041221201
custom_field_three
ENCRUSTATION
custom_field_two
3
customer
1
datetime
2021-04-13T00:22:05-07:00
documentation
PROPIPE
is_lateral_inspection
false