Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 13, 2021, 05:22 AM
  • C 0289_C 0288_04122021_224325.mp4

Date
04/12/2021
W/O
885817
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00134
PipeID
P09749
Time
10:22 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8727
Sewer Name
C JOINT OUTFALL C - UNIT 6E
City
LAKEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
06
Purpose
Routine Assessment
Project
RFIR_WO_885817_TV19035_APR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
27 in.
Upstream MH
C 0289
Downstream MH
C 0288
Dir. of Survey
Downstream
Length Surveyed
485 ft.
Total Length
485 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4331
O&M Rating
21
Overall Index
3
Overall Quick
Overall Rating
21
Pipe schematic from manhole C 0289 to C 0288
MH: C 0289MH: C 0288downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 02890 ft. MWM - Water Mark, 25 %of cross sectional area2.6 ft. MGO - General Observation - MAG COAT41.2 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES68.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"88.7 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES88.7 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 12 o'clock, , within 8 inches of joint: YES117.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"173.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"194.3 ft. IR - Infiltration Runner, at 01 o'clock, within 8 inches of joint: YES221.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"302 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"374.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"422.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"442 ft. IR - Infiltration Runner, from 08 to 04 o'clock, within 8 inches of joint: YES450.6 ft. IR - Infiltration Runner, at 02 o'clock, within 8 inches of joint: YES450.6 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES456.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"470.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"485 ft. AMH - Downstream Manhole, Survey Ends - C 0288

Observation photos (7)

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES

    41.2 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    88.7 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 12 o'clock,  , within 8 inches of joint: YES

    88.7 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 12 o'clock, , within 8 inches of joint: YES

  • Infiltration Runner, at 01 o'clock, within 8 inches of joint: YES

    194.3 ft. - Infiltration Runner, at 01 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, from 08 to 04 o'clock, within 8 inches of joint: YES

    442 ft. - Infiltration Runner, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Infiltration Runner, at 02 o'clock, within 8 inches of joint: YES

    450.6 ft. - Infiltration Runner, at 02 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 09 o'clock,  , within 8 inches of joint: YES

    450.6 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
456.4TF
88.7ID
0MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
173.2TFC
485AMHC 0288
41.2DAE
302TFC
0MWL
374.3TFC
0AMHC 0289
450.6IR
2.6MGOMAG COAT
221.6TFC
442IR
0MWM
422.4TFC
470.5TFC
88.7DAE
194.3IR
68.7TFC
450.6DAE
117.4TFC

Properties (7)

additional_info
630074041221201
custom_field_three
INFILTRATION
custom_field_two
3
customer
1
datetime
2021-04-12T22:22:50-07:00
documentation
PROPIPE
is_lateral_inspection
false