- Date
- 04/13/2021
- W/O
- 887836
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00521
- PipeID
- P05954
- Time
- 10:36 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8829
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #1
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- CA_WO_887836
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 05 0731
- Downstream MH
- 05 0730
- Dir. of Survey
- Downstream
- Length Surveyed
- 107.4 ft.
- Total Length
- 107.4 ft.
- Structural Index
- 3
- Structural Quick
- 413C
- Structural Rating
- 67
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 67
Pipe schematic from manhole 05 0731 to 05 0730 Observation photos (5)

4.2 ft. - Crack Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

7.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

38.1 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 8"

46.2 ft. - Fracture Multiple, from 04 to 09 o'clock, within 8 inches of joint: YES

68 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"