Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2021, 09:57 AM
  • 15 0061_15 1044_04072021_030814.mp4

Date
04/07/2021
W/O
887826
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00622
PipeID
P21479
Time
2:57 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8812
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
CA_WO_887826
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 1044
Downstream MH
15 0061
Dir. of Survey
Upstream
Length Surveyed
86 ft.
Total Length
86 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 15 1044 to 15 0061
MH: 15 1044MH: 15 0061upstream0 ft. MSA - Survey Abandoned - COMPLETED REVERSAL1.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES6.6 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES10.4 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES27.8 ft. FS - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES86 ft. MWL - Water Level, 15 %of cross sectional area86 ft. MWM - Water Mark, 25 %of cross sectional area86 ft. AMH - Downstream Manhole, Survey Begins - 15 1044

Observation photos (5)

  • Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES

    58.2 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    75.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES

    79.4 ft. - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    84.9 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - COMPLETED REVERSAL

    86 ft. - Survey Abandoned - COMPLETED REVERSAL

Observations (8)

DistanceCodeObservation
84.9CM
86MSACOMPLETED REVERSAL
0MWL
0MWM
0AMH15 1044
75.6CM
79.4FC
58.2FS

Properties (6)

custom_field_three
BROKEN, CRACKS, FRACTURES
custom_field_two
1
customer
1
datetime
2021-04-07T02:57:40-07:00
documentation
PRO PIPE
is_lateral_inspection
false