Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2021, 09:01 AM
  • 15 0058_15 0057_04072021_022146.mp4

Date
04/07/2021
W/O
887826
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00622
PipeID
P11951
Time
2:01 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8812
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
38
Purpose
Routine Assessment
Project
CA_WO_887826
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
15 0057
Downstream MH
15 0058
Dir. of Survey
Upstream
Length Surveyed
290.8 ft.
Total Length
290.8 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
3
O&M Quick
3A2A
O&M Rating
53
Overall Index
3
Overall Quick
Overall Rating
57
Pipe schematic from manhole 15 0057 to 15 0058
MH: 15 0057MH: 15 0058upstream0 ft. MSA - Survey Abandoned - COMPLETED REVERSAL23.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"47.2 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"73.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"97.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"123.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"147.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"174.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"183.7 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish198.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"224.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 8", 8"234.2 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start234.2 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish241.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES248.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"272.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"288.8 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start290.8 ft. MWL - Water Level, 5 %of cross sectional area290.8 ft. AMH - Downstream Manhole, Survey Begins - 15 0057290.8 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (4)

  • Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    49.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Settled Fine,  10 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    56.6 ft. - Deposits Settled Fine, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Survey Abandoned - COMPLETED REVERSAL

    290.8 ft. - Survey Abandoned - COMPLETED REVERSAL

Observations (20)

DistanceCodeObservation
56.6DSF
166.9TFC
42.2TF
107.1DSF
0MWL
217.1TFC
49.3FM
290.8MSACOMPLETED REVERSAL
66.1TFA
267.3TFC
0AMH15 0057
243.6TF
56.6DAGS
143.2TFC
193.5TFC
92.6TFC
18.5TFC
2DAGS
0MWM
116.3TFC

Properties (6)

custom_field_three
CRACKS FRACTURES
custom_field_two
3
customer
1
datetime
2021-04-07T02:01:15-07:00
documentation
PRO PIPE
is_lateral_inspection
false