Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2021, 07:51 AM
  • 15 0041_15 0040_04072021_005643.mp4

Date
04/07/2021
W/O
887826
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00622
PipeID
P11931
Time
12:51 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8812
Sewer Name
15 PUENTE TRUNK
City
CITY OF INDUSTRY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
35
Purpose
Routine Assessment
Project
CA_WO_887826
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
15 0041
Downstream MH
15 0040
Dir. of Survey
Downstream
Length Surveyed
16.8 ft.
Total Length
16.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 15 0041 to 15 0040
MH: 15 0041MH: 15 0040downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 00410 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start9 ft. FS - Fracture Spiral, from 07 to 05 o'clock, within 8 inches of joint: YES16.7 ft. DSF - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish16.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0040

Observation photos (2)

  • Deposits Settled Fine,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Settled Fine, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Spiral, from 07 to 05 o'clock, within 8 inches of joint: YES

    9 ft. - Fracture Spiral, from 07 to 05 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
9FS
0AMH15 0041
16.7DSF
0MWM
2DSF
0MWL
16.8AMH15 0040

Properties (6)

custom_field_three
FRACTURE
custom_field_two
2
customer
1
datetime
2021-04-07T00:51:44-07:00
documentation
PRO PIPE
is_lateral_inspection
false