Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2021, 10:38 AM
  • 01 0056_01 0055_03312021_035341.mp4

Date
03/31/2021
W/O
886006
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00209
PipeID
P00725
Time
3:38 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8715
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_886006_TV01254_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 0056
Downstream MH
01 0055
Dir. of Survey
Downstream
Length Surveyed
349.7 ft.
Total Length
349.7 ft.
Structural Index
3
Structural Quick
423M
Structural Rating
215
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
219
Pipe schematic from manhole 01 0056 to 01 0055
MH: 01 0056MH: 01 0055downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 00560 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start76.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"79 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"124.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"128 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"131.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"179.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"191.2 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES225.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"228.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"277.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"280.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"287.2 ft. FM - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES328.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"331.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"349.7 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK349.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish349.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED349.7 ft. AMH - Downstream Manhole, Survey Ends - 01 0055

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    191.2 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    287.2 ft. - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
3.1CM
76.4TFC
328.9TFC
287.2FM
0MGOCONNECTION AT THE MH 3 OC'LOCK
124.9TF
280.1TF
131.1TFC
225.5TFC
0MGOCONNECTION AT THE MH 9 OC'LOCK
0AMH01 0056
79TFC
0MWM
179.4TFC
349.7MGOCONNECTION AT THE MH 3 OC'LOCK
0MWL
349.7CM
128TFC
191.2FM
331.4TFC
228.2TFC
349.7MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
349.7AMH01 0055
277.1TFC
177.3TFC

Properties (7)

additional_info
630074033021207
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-31T03:38:53-07:00
documentation
PROPIPE
is_lateral_inspection
false