Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 6, 2021, 07:38 AM
  • 05 0757_05 2275_04072021_004642.mp4

Date
04/06/2021
W/O
886017
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00484
PipeID
P05984
Time
12:38 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8720
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_886017_TV05315_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
8 in.
Upstream MH
05 2275
Downstream MH
05 0757
Dir. of Survey
Upstream
Length Surveyed
188.3 ft.
Total Length
188.3 ft.
Structural Index
4
Structural Quick
4F00
Structural Rating
148
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
148
Pipe schematic from manhole 05 2275 to 05 0757
MH: 05 2275MH: 05 0757upstream0 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 05 0757185.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start188.3 ft. AMH - Downstream Manhole, Survey Begins - 05 2275188.3 ft. MWM - Water Mark, 25 %of cross sectional area188.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK188.3 ft. MWL - Water Level, 15 %of cross sectional area188.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH05 2275
0MWM
0MGOCONNECTION AT THE MH 3 OC'LOCK
3.1FM
188.3FM
0MWL
188.3AMH05 0757
0MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074040621201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-04-06T00:38:47-07:00
documentation
PROPIPE
is_lateral_inspection
false