Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2021, 07:28 AM
  • 05 2275_05 0756_04072021_003738.mp4

Date
04/07/2021
W/O
886017
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00484
PipeID
P05983
Time
12:28 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8720
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_886017_TV05315_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
05 0756
Downstream MH
05 2275
Dir. of Survey
Upstream
Length Surveyed
232.2 ft.
Total Length
232.2 ft.
Structural Index
4
Structural Quick
4H00
Structural Rating
180
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
180
Pipe schematic from manhole 05 0756 to 05 2275
MH: 05 0756MH: 05 2275upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 22750 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK227 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start232.2 ft. AMH - Downstream Manhole, Survey Begins - 05 0756232.2 ft. MWL - Water Level, 15 %of cross sectional area232.2 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
232.2AMH05 2275
0AMH05 0756
0MWL
232.2MGOCONNECTION AT THE MH 3 OC'LOCK
232.2FM
0MWM
5.2FM
232.2MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074040621201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-04-07T00:28:52-07:00
documentation
PROPIPE
is_lateral_inspection
false