Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2021, 09:15 AM
  • E 0211_E 0094_04072021_022552.mp4

Date
04/07/2021
W/O
886017
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00484
PipeID
P05979
Time
2:15 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8720
Sewer Name
05 MANCHESTER-VERMONT RELIEF TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_886017_TV05315_APR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
E 0211
Downstream MH
E 0094
Dir. of Survey
Downstream
Length Surveyed
370.3 ft.
Total Length
370.3 ft.
Structural Index
4
Structural Quick
4N00
Structural Rating
292
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
292
Pipe schematic from manhole E 0211 to E 0094
MH: E 0211MH: E 0094downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - E 02110 ft. MWL - Water Level, 5 %of cross sectional area3.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start370.2 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK370.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK370.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish370.3 ft. AMH - Downstream Manhole, Survey Ends - E 0094

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
370.3AMHE 0094
0MWM
370.2MGOCONNECTION AT THE MH 9 OC'LOCK
0AMHE 0211
370.2MGOCONNECTION AT THE MH 3 OC'LOCK
0MWL
3.1FM
370.2FM

Properties (7)

additional_info
630074040621201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-04-07T02:15:06-07:00
documentation
PROPIPE
is_lateral_inspection
false