- Date
- 03/18/2021
- W/O
- 880430
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00210
- PipeID
- P01951
- Time
- 2:26 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8752
- Sewer Name
- 01 HUNTINGTON PARK TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- RFIR_WO_880430_TV01247_MAR2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 18 in.
- Width
- 24 in.
- Upstream MH
- 01 1101
- Downstream MH
- 01 1100
- Dir. of Survey
- Downstream
- Length Surveyed
- 299.5 ft.
- Total Length
- 299.5 ft.
- Structural Index
- 2
- Structural Quick
- 3K2M
- Structural Rating
- 313
- O&M Index
- 2
- O&M Quick
- 2V11
- O&M Rating
- 231
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 544
Pipe schematic from manhole 01 1101 to 01 1100 Observation photos (6)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

46.2 ft. - Roots Fine Lateral, from 02 to 04 o'clock

144.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

153.1 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

299.5 ft. - General Observation - ROACHES @ MH