Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 19, 2021, 06:31 AM
  • 01 1095_01 1094A_03182021_234210.mp4

Date
03/18/2021
W/O
880430
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00210
PipeID
P01945
Time
11:31 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8754
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_880430_TV01247_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
24 in.
Upstream MH
01 1095
Downstream MH
01 1094A
Dir. of Survey
Downstream
Length Surveyed
360.3 ft.
Total Length
360.3 ft.
Structural Index
3
Structural Quick
3G21
Structural Rating
116
O&M Index
2
O&M Quick
2M00
O&M Rating
144
Overall Index
2
Overall Quick
Overall Rating
260
Pipe schematic from manhole 01 1095 to 01 1094A
MH: 01 1095MH: 01 1094Adownstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 10952 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start136.6 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: NO, 6", 2" - ACTIVE156.5 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES358 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish358 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish360.3 ft. MGO - General Observation - ROACHES @ MH360.3 ft. AMH - Downstream Manhole, Survey Ends - 01 1094A360.3 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: NO, 6", 2" - ACTIVE

    136.6 ft. - Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: NO, 6", 2" - ACTIVE

  • General Observation - ROACHES @ MH

    360.3 ft. - General Observation - ROACHES @ MH

Observations (12)

DistanceCodeObservation
360.3MGOROACHES @ MH
0MWL
2DAGS
0MWM
136.6TBIACTIVE
2CM
360.3AMH01 1094A
358DAGS
156.5CL
358CM
0AMH01 1095
360.3MGOCONN @ MH 3 O'CLOCK/ACTIVE

Properties (7)

additional_info
630069031821201
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-18T23:31:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false