- Date
- 03/19/2021
- W/O
- 880430
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00210
- PipeID
- P01936
- Time
- 2:51 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8754
- Sewer Name
- 01 HUNTINGTON PARK TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- RFIR_WO_880430_TV01247_MAR2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 24 in.
- Upstream MH
- 01 1087
- Downstream MH
- 01 1086
- Dir. of Survey
- Downstream
- Length Surveyed
- 461.8 ft.
- Total Length
- 461.8 ft.
- Structural Index
- 3
- Structural Quick
- 443Q
- Structural Rating
- 462
- O&M Index
- 2
- O&M Quick
- 2Q00
- O&M Rating
- 184
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 646
Pipe schematic from manhole 01 1087 to 01 1086 Observation photos (5)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

442.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

461.8 ft. - General Observation - ROACHES @ MH