Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 17, 2021, 07:49 AM
  • 01 1125_01 1124_03172021_010308.mp4

Date
03/17/2021
W/O
880430
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00210
PipeID
P01977
Time
12:49 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8751
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_880430_TV01247_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
01 1124
Downstream MH
01 1125
Dir. of Survey
Upstream
Length Surveyed
146.2 ft.
Total Length
146.2 ft.
Structural Index
3
Structural Quick
3E2E
Structural Rating
143
O&M Index
2
O&M Quick
322E
O&M Rating
67
Overall Index
2
Overall Quick
Overall Rating
210
Pipe schematic from manhole 01 1124 to 01 1125
MH: 01 1124MH: 01 1125upstream0 ft. MSA - Survey Abandoned - DUE TO OBSTACLE/PLUMBERS SNAKE.0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.7 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"2.7 ft. MGO - General Observation - PLUMBERS SNAKE AT THIS LATERAL7.2 ft. DAR - Deposits Attached Ragging, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES7.2 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 01 to 08 o'clock - PLUMBERS SNAKE22.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"26.2 ft. RFL - Roots Fine Lateral, from 01 to 04 o'clock26.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"71.9 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4", 6" - BROKEN CONN/OPEN144.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start144.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start144.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start146.2 ft. MWM - Water Mark, 20 %of cross sectional area146.2 ft. AMH - Downstream Manhole, Survey Begins - 01 1124146.2 ft. MGO - General Observation - ROACHES @ MH146.2 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (8)

  • General Observation - ROACHES @ MH

    0 ft. - General Observation - ROACHES @ MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Lateral, from 01 to 04 o'clock

    120 ft. - Roots Fine Lateral, from 01 to 04 o'clock

  • Deposits Attached Ragging, 15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    139 ft. - Deposits Attached Ragging, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

  • Obstacles Other, 20 %of cross sectional area, from 01 to 08 o'clock - PLUMBERS SNAKE

    139 ft. - Obstacles Other, 20 %of cross sectional area, from 01 to 08 o'clock - PLUMBERS SNAKE

  • General Observation - PLUMBERS SNAKE AT THIS LATERAL

    143.5 ft. - General Observation - PLUMBERS SNAKE AT THIS LATERAL

  • Survey Abandoned - DUE TO OBSTACLE/PLUMBERS SNAKE.

    146.2 ft. - Survey Abandoned - DUE TO OBSTACLE/PLUMBERS SNAKE.

Observations (20)

DistanceCodeObservation
2DAGS
77.5TFA
139DAR
0MWM
0AMH01 1124
146.2MSADUE TO OBSTACLE/PLUMBERS SNAKE.
0MGOROACHES @ MH
146.2CM
144SSS
146.2DAGS
74.3TFDBROKEN CONN/OPEN
120RFL
143.5TFA
139OBZPLUMBERS SNAKE
143.5MGOPLUMBERS SNAKE AT THIS LATERAL
2CM
123.7TFC
0MWL
120TFA
2SSS

Properties (7)

additional_info
630069031621201
custom_field_three
ABANDONED DUE TO OBSTACLE
custom_field_two
5
customer
1
datetime
2021-03-17T00:49:25-07:00
documentation
PRO PIPE
is_lateral_inspection
false