Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 8, 2021, 05:04 AM
  • 15 0706_15 0705_04072021_222305.mp4

Date
04/07/2021
W/O
887655
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00602
PipeID
P12598
Time
10:04 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8813
Sewer Name
15 EL MONTE AVENUE TRUNK
City
ARCADIA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
Routine Assessment
Project
CA_WO_887655
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
15 0706
Downstream MH
15 0705
Dir. of Survey
Downstream
Length Surveyed
331.5 ft.
Total Length
331.5 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
328
O&M Index
2
O&M Quick
4134
O&M Rating
146
Overall Index
2
Overall Quick
Overall Rating
474
Pipe schematic from manhole 15 0706 to 15 0705
MH: 15 0706MH: 15 0705downstream0 ft. AMH - Upstream Manhole, Survey Begins - 15 07060 ft. MGO - General Observation - ROACHES @ MH0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES208.4 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 4", 8" - 95% ROOTS/ACTIVE208.5 ft. RBL - Roots Ball Lateral, from 12 to 12 o'clock, 100 %208.5 ft. RMC - Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES227.7 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR248 ft. RMJ - Roots Medium Joint, at 05 o'clock, 10 %, within 8 inches of joint: YESR328.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish329 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish329 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish331.5 ft. MGO - General Observation - ROACHES @ MH331.5 ft. AMH - Downstream Manhole, Survey Ends - 15 0705

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    7.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In Defective, at 02 o'clock, -,  , within 8 inches of joint: YES, 4", 8" - 95% ROOTS/ACTIVE

    208.4 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: YES, 4", 8" - 95% ROOTS/ACTIVE

  • Roots Ball Lateral, from 12 to 12 o'clock, 100 %

    208.5 ft. - Roots Ball Lateral, from 12 to 12 o'clock, 100 %

  • Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES

    208.5 ft. - Roots Medium Connection, at 02 o'clock, 10 %, within 8 inches of joint: YES

  • Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR

    227.7 ft. - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR

  • Roots Medium Joint, at 05 o'clock, 10 %, within 8 inches of joint: YESR

    248 ft. - Roots Medium Joint, at 05 o'clock, 10 %, within 8 inches of joint: YESR

Observations (19)

DistanceCodeObservation
0AMH15 0706
227.7RMJ
0MGOROACHES @ MH
2SSS
2CM
329DAGS
248RMJ
0MWL
331.5MGOROACHES @ MH
0MWM
331.5AMH15 0705
208.5RBL
329SSS
208.4TBD95% ROOTS/ACTIVE
328.9CM
2DAGS
208.5RMC
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
7.8CM

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-04-07T22:04:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false