Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 3, 2021, 09:05 AM
  • 14 0104A_14 0104_03032021_021011.mp4

Date
03/03/2021
W/O
879965
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00577
PipeID
P18130
Time
1:05 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8588
Sewer Name
14 TRUNK "A"
City
LANCASTER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
18
Purpose
Routine Assessment
Project
WO_879965_TV14017_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
14 0104
Downstream MH
14 0104A
Dir. of Survey
Upstream
Length Surveyed
47.3 ft.
Total Length
47.3 ft.
Structural Index
2
Structural Quick
2900
Structural Rating
18
O&M Index
2
O&M Quick
2900
O&M Rating
18
Overall Index
2
Overall Quick
Overall Rating
36
Pipe schematic from manhole 14 0104 to 14 0104A
MH: 14 0104MH: 14 0104Aupstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 14 0104A2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish22.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"45.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start45.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47.3 ft. MWM - Water Mark, 25 %of cross sectional area47.3 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE47.3 ft. MWL - Water Level, 20 %of cross sectional area47.3 ft. AMH - Downstream Manhole, Survey Begins - 14 0104

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
45.3DAGS
0MWM
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
25.1TFC
47.3MGOCONN @ MH 3 O'CLOCK/ACTIVE
2DAGS
2SSS
45SSS
0AMH14 0104
47.3AMH14 0104A

Properties (7)

additional_info
630069030221201
custom_field_three
LIGHT GREASE
custom_field_two
3
customer
1
datetime
2021-03-03T01:05:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false