Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 20, 2021, 11:13 AM
  • B 0476_B 0475A_4202021_042814.mp4

Date
04/20/2021
W/O
0891491
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00094
PipeID
P09001
Time
4:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1781
Sewer Name
B JOINT OUTFALL B - UNIT 5D
City
ALTADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
06
Purpose
Maintenance Related
Project
20210420MDM_JOINT_OUTFALL_B_UNIT_5D
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
B 0475A
Downstream MH
B 0476
Dir. of Survey
Upstream
Length Surveyed
167.3 ft.
Total Length
167.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole B 0475A to B 0476
MH: B 0475AMH: B 0476upstream0 ft. AMH - Upstream Manhole, Survey Ends - 4:40AM98.4 ft. RFJ - Roots Fine Joint, from 01 to 04 o'clock, within 8 inches of joint: YESR - 2%167.3 ft. MWL - Water Level, 20 %of cross sectional area167.3 ft. AMH - Downstream Manhole, Survey Begins - 4:30AM167.3 ft. MWM - Water Mark, 40 %of cross sectional area

Observations (5)

DistanceCodeObservation
0MWL
167.3AMH4:40AM
68.9RFJ2%
0AMH4:30AM
0MWM

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2021-04-20T04:13:46-07:00
documentation
MARTIN,CASTILLO,RUVALCABA
is_lateral_inspection
false