Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2021, 05:46 AM
  • 01 0518_01 0517_03012021_230159.mp4

Date
03/01/2021
W/O
880271
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00206
PipeID
P01002
Time
9:46 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8586
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_880271_TV01232_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0518
Downstream MH
01 0517
Dir. of Survey
Downstream
Length Surveyed
316.6 ft.
Total Length
316.6 ft.
Structural Index
3
Structural Quick
513K
Structural Rating
191
O&M Index
2
O&M Quick
412L
O&M Rating
130
Overall Index
3
Overall Quick
Overall Rating
321
Pipe schematic from manhole 01 0518 to 01 0517
MH: 01 0518MH: 01 0517downstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 01 05180 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start6.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start15 ft. MWL - Water Level, 25 %of cross sectional area15 ft. MWM - Water Mark, 30 %of cross sectional area68.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"77 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"99.2 ft. BSV - Broken Soil Visible, from 10 to 12 o'clock, within 8 inches of joint: YES101.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"133.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"178.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"197.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"202.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"229.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"250 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"279.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"304.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"311.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"315.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish315.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish316.6 ft. AMH - Downstream Manhole, Survey Ends - 01 0517316.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    6.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Broken Soil Visible, from 10 to 12 o'clock, within 8 inches of joint: YES

    99.2 ft. - Broken Soil Visible, from 10 to 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    316.6 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (28)

DistanceCodeObservation
197.2TFA
99.2BSV
15MWL
252.5TFC
0MGOCOCKROACHES IN MANHOLE
2DAGS
68.1TFA
279.4TFC
229.5TFC
316.6AMH01 0517
15MWM
315.5CM
0MGOCONNECTION AT MH 3 O'CLOCK
0AMH01 0518
311.9TFA
6.5CM
151.6TFC
133.9TFC
77TFC
178.4TFC
101.6TFA
0MWM
304.3TFC
250TFC
315.5DAGS
202.3TFC
0MWL
316.6MGOCOCKROACHES IN MANHOLE

Properties (7)

additional_info
630069030121201
custom_field_three
MULTIPLE CRACKS/BROKEN PIPE
custom_field_two
2
customer
1
datetime
2021-03-01T21:46:58-08:00
documentation
PRO PIPE
is_lateral_inspection
false