Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 24, 2021, 05:02 AM
  • 02 0994A_02 0994_03232021_220947.mp4

  • 02 0994A_02 0994_03232021_220947.mp4

Date
03/23/2021
W/O
880108
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00279
PipeID
P03567
Time
10:02 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8801
Sewer Name
02 MONTEBELLO TRUNK
City
COMMERCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_880108_TV02387_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
02 0994A
Downstream MH
02 0994
Dir. of Survey
Downstream
Length Surveyed
72.7 ft.
Total Length
72.7 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
42
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
42
Pipe schematic from manhole 02 0994A to 02 0994
MH: 02 0994AMH: 02 0994downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 0994A2.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start70.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish72.7 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK72.7 ft. AMH - Downstream Manhole, Survey Ends - 02 0994

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
72.7MGOCONNECTION AT MH, 3 O'CLOCK
0MWL
0MGOCONNECTION AT MH, 3 O'CLOCK
72.7AMH02 0994
0MWM
0AMH02 0994A
2.5CM
70.4CM

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-23T22:02:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false