Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 15, 2021, 11:12 AM
  • 18 1099_18 1098_03152021_050055.mp4

Date
03/15/2021
W/O
880095
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00699
PipeID
P14265
Time
4:12 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8636
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_880095_TV18196_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 1099
Downstream MH
18 1098
Dir. of Survey
Downstream
Length Surveyed
645.3 ft.
Total Length
645.3 ft.
Structural Index
4
Structural Quick
4632
Structural Rating
30
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
30
Pipe schematic from manhole 18 1099 to 18 1098
MH: 18 1099MH: 18 1098downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 10990 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area402.8 ft. FM - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES433.3 ft. FS - Fracture Spiral, from 04 to 07 o'clock, within 8 inches of joint: YES448.1 ft. FM - Fracture Multiple, from 05 to 09 o'clock, within 8 inches of joint: YES463.5 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start500.6 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish585.9 ft. FM - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES626.1 ft. FS - Fracture Spiral, from 05 to 07 o'clock, within 8 inches of joint: YES636.5 ft. FM - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES641 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES641 ft. IS - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES645.3 ft. AMH - Downstream Manhole, Survey Ends - 18 1098

Observation photos (9)

  • Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    402.8 ft. - Fracture Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 04 to 07 o'clock, within 8 inches of joint: YES

    433.3 ft. - Fracture Spiral, from 04 to 07 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 05 to 09 o'clock, within 8 inches of joint: YES

    448.1 ft. - Fracture Multiple, from 05 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    463.5 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

    585.9 ft. - Fracture Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 05 to 07 o'clock, within 8 inches of joint: YES

    626.1 ft. - Fracture Spiral, from 05 to 07 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    636.5 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    641 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES

    641 ft. - Infiltration Stain, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
448.1FM
636.5FM
402.8FM
0AMH18 1099
500.6FM
626.1FS
0MWM
0MWL
463.5FM
585.9FM
433.3FS
645.3AMH18 1098
641FM
641IS

Properties (7)

custom_field_three
FRACTURES
custom_field_two
3
customer
1
datetime
2021-03-15T04:12:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
26802