- Date
- 03/25/2021
- W/O
- 885860
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00599
- PipeID
- P12677
- Time
- 11:39 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8807
- Sewer Name
- 15 CALIFORNIA AVENUE TRUNK
- City
- MONROVIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 05
- Purpose
- Routine Assessment
- Project
- RFIR_WO_885860_TV15182_APR2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 15 0884
- Downstream MH
- 15 0883
- Dir. of Survey
- Downstream
- Length Surveyed
- 311.7 ft.
- Total Length
- 311.7 ft.
- Structural Index
- 3
- Structural Quick
- 3K2K
- Structural Rating
- 305
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 305
Pipe schematic from manhole 15 0884 to 15 0883 Observation photos (5)

2.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.6 ft. - General Observation - MAG COAT

2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

6.8 ft. - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: YES, 8"

66.2 ft. - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8" - TOP HAT