Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 29, 2021, 09:53 AM
  • 15 0876_15 0875_03292021_030135.mp4

Date
03/29/2021
W/O
885860
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00599
PipeID
P12669
Time
2:53 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8763
Sewer Name
15 CALIFORNIA AVENUE TRUNK
City
MONROVIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
05
Purpose
Routine Assessment
Project
RFIR_WO_885860_TV15182_APR2021
Sewer Type
Gravity
Material
NRCP
Shape
Square
Height
15 in.
Width
15 in.
Upstream MH
15 0876
Downstream MH
15 0875
Dir. of Survey
Downstream
Length Surveyed
144.7 ft.
Total Length
144.7 ft.
Structural Index
3
Structural Quick
3E00
Structural Rating
84
O&M Index
2
O&M Quick
2E00
O&M Rating
56
Overall Index
3
Overall Quick
Overall Rating
140
Pipe schematic from manhole 15 0876 to 15 0875
MH: 15 0876MH: 15 0875downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 08760 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. MGO - General Observation - MAG COATING THROUGHOUT2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start141.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish142.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish144.7 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK144.7 ft. AMH - Downstream Manhole, Survey Ends - 15 0875

Observation photos (3)

  • General Observation - MAG COATING THROUGHOUT

    2 ft. - General Observation - MAG COATING THROUGHOUT

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
2MGOMAG COATING THROUGHOUT
142.5SAV
0MWL
144.7MGOCONNECTION AT MH 3 O'CLOCK
144.7AMH15 0875
0AMH15 0876
142.5DAGS
2SAV
141.5TFC
2DAGS
0MWM

Properties (7)

additional_info
630069032921002
custom_field_three
VISIBLE AGGREGATE
custom_field_two
3
customer
1
datetime
2021-03-29T02:53:46-07:00
documentation
PRO PIPE
is_lateral_inspection
false