Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2021, 08:26 AM
  • 15 0207_15 0206_03112021_013137.mp4

Date
03/11/2021
W/O
880319
Weather
Damp
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00620
PipeID
P12129
Time
12:26 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8633
Sewer Name
15 PECK ROAD TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
17
Purpose
Routine Assessment
Project
WO_880319_TV15022_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0207
Downstream MH
15 0206
Dir. of Survey
Downstream
Length Surveyed
41.9 ft.
Total Length
41.9 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
2
O&M Quick
2700
O&M Rating
14
Overall Index
2
Overall Quick
Overall Rating
21
Pipe schematic from manhole 15 0207 to 15 0206
MH: 15 0207MH: 15 0206downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 15 02072.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start6.2 ft. CM - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES18.8 ft. FM - Fracture Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES38.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish41.9 ft. AMH - Downstream Manhole, Survey Ends - 15 020641.9 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

    6.2 ft. - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

    18.8 ft. - Fracture Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
0MWM
2.4DAGS
6.2CM
0MWL
18.8FM
0MGOCONNECTION AT MH, 9 O'CLOCK
38.3DAGS
0AMH15 0207
41.9AMH15 0206
41.9MGOCONNECTION AT MH, 9 O'CLOCK

Properties (6)

custom_field_three
CRACKS, FRACTURES
custom_field_two
3
customer
1
datetime
2021-03-11T00:26:50-08:00
documentation
PRO PIPE
is_lateral_inspection
false