Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2021, 09:18 AM
  • 15 0203_15 0202_03112021_023622.mp4

Date
03/11/2021
W/O
880319
Weather
Light Rain
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00620
PipeID
P12125
Time
1:18 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8633
Sewer Name
15 PECK ROAD TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
17
Purpose
Routine Assessment
Project
WO_880319_TV15022_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0203
Downstream MH
15 0202
Dir. of Survey
Downstream
Length Surveyed
230.8 ft.
Total Length
230.8 ft.
Structural Index
3
Structural Quick
3321
Structural Rating
11
O&M Index
2
O&M Quick
2H00
O&M Rating
90
Overall Index
2
Overall Quick
Overall Rating
101
Pipe schematic from manhole 15 0203 to 15 0202
MH: 15 0203MH: 15 0202downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 15 02030 ft. MWM - Water Mark, 35 %of cross sectional area2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start28.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES79.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"112.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"172.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES188.6 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES190.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"207.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"217.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES228.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish230.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0202

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    28.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    172.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    188.6 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"

    207.6 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    217.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
217.4CM
228.6DAGS
0MWL
0MGOCONNECTION AT MH, 9 O'CLOCK
2.2DAGS
172.7CM
79.7TF
190.1TFC
28.9CM
207.6TBA
188.6CL
230.8AMH15 0202
0AMH15 0203
112.2TF
0MWM

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-11T01:18:09-08:00
documentation
PRO PIPE
is_lateral_inspection
false