Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 12, 2021, 06:24 AM
  • 15 0198_15 0197_03112021_234559.mp4

Date
03/11/2021
W/O
880319
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00620
PipeID
P12120
Time
10:24 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8634
Sewer Name
15 PECK ROAD TRUNK
City
EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
17
Purpose
Routine Assessment
Project
WO_880319_TV15022_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
15 0198
Downstream MH
15 0197
Dir. of Survey
Downstream
Length Surveyed
354.8 ft.
Total Length
354.8 ft.
Structural Index
3
Structural Quick
3J21
Structural Rating
170
O&M Index
2
O&M Quick
332M
O&M Rating
151
Overall Index
2
Overall Quick
Overall Rating
321
Pipe schematic from manhole 15 0198 to 15 0197
MH: 15 0198MH: 15 0197downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 15 01980 ft. MWM - Water Mark, 35 %of cross sectional area2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start56.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES69 ft. CS - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES77.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start111.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"198 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"233.7 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR239.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"245.9 ft. RFJ - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES254.1 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR263.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 8"287 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES316.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"349.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 8"349.8 ft. RML - Roots Medium Lateral, from 02 to 04 o'clock, 10 %, within 8 inches of joint: YES352.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish354.8 ft. AMH - Downstream Manhole, Survey Ends - 15 0197

Observation photos (9)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    56.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

    69 ft. - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    77.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR

    233.7 ft. - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR

  • Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

    245.9 ft. - Roots Fine Joint, at 08 o'clock, within 8 inches of joint: YES

  • Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR

    254.1 ft. - Roots Medium Joint, from 08 to 04 o'clock, 5 %, within 8 inches of joint: YESR

  • Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES

    287 ft. - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YES

  • Roots Medium Lateral, from 02 to 04 o'clock, 10 %, within 8 inches of joint: YES

    349.8 ft. - Roots Medium Lateral, from 02 to 04 o'clock, 10 %, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
287RFJ
0MWL
0AMH15 0198
254.1RMJ
239.3TFC
352.1CM
245.9RFJ
2.2DAGS
354.8AMH15 0197
349.8TF
233.7RMJ
69CS
349.8RML
352.1DAGS
56.8CM
0MWM
198TF
111.4TFA
316.7TF
263.9TFA
77.3CM

Properties (6)

custom_field_three
multiple cracks
custom_field_two
3
customer
1
datetime
2021-03-11T22:24:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false