- Date
- 03/16/2021
- W/O
- 880300
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00699
- PipeID
- P14243
- Time
- 3:05 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8638
- Sewer Name
- 18 SANTA FE STREET RELIEF TRUNK
- City
- S. WHITTIER
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_880300_TV18173_MAR2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0408
- Downstream MH
- 18 0407
- Dir. of Survey
- Downstream
- Length Surveyed
- 455.9 ft.
- Total Length
- 455.9 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 2
- O&M Quick
- 2211
- O&M Rating
- 5
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 10
Pipe schematic from manhole 18 0408 to 18 0407 Observation photos (6)

2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - General Observation - MAG COAT

2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

9.8 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

12.8 ft. - Roots Fine Barrell, at 12 o'clock

13.7 ft. - Roots Fine Barrell, at 02 o'clock