Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 3, 2021, 10:19 AM
  • 05 1758_05 1727_03032021_032424.mp4

Date
03/03/2021
W/O
880429
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00471
PipeID
P06985
Time
2:19 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8493
Sewer Name
05 LOMITA TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
WO_880429_TV05130_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
18 in.
Upstream MH
05 1758
Downstream MH
05 1727
Dir. of Survey
Downstream
Length Surveyed
103.2 ft.
Total Length
103.2 ft.
Structural Index
3
Structural Quick
3400
Structural Rating
12
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
12
Pipe schematic from manhole 05 1758 to 05 1727
MH: 05 1758MH: 05 1727downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 17580 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area33.4 ft. CM - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES49.2 ft. CM - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES53.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES91.8 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES103.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1727103.2 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK103.2 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (4)

  • Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

    33.4 ft. - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

    49.2 ft. - Crack Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    53.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    91.8 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
49.2CM
0AMH05 1758
91.8CM
53.2CM
0MWM
103.2AMH05 1727
0MWL
103.2MGOCONNECTION AT THE MH 3 OC'LOCK
33.4CM
103.2MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074030221201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-03-03T02:19:15-08:00
documentation
PROPIPE
is_lateral_inspection
false