Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2021, 09:03 AM
  • 05 1749_05 1748_03022021_021408.mp4

Date
03/02/2021
W/O
880429
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00471
PipeID
P06976
Time
1:03 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8492
Sewer Name
05 LOMITA TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
WO_880429_TV05130_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
18 in.
Upstream MH
05 1749
Downstream MH
05 1748
Dir. of Survey
Downstream
Length Surveyed
382.9 ft.
Total Length
382.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2N00
O&M Rating
154
Overall Index
2
Overall Quick
Overall Rating
154
Pipe schematic from manhole 05 1749 to 05 1748
MH: 05 1749MH: 05 1748downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 17492 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start5.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: NO7.6 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"82.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"159.3 ft. TSA - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"380 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish382.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1748

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: NO

    5.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: NO

  • Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    159.3 ft. - Tap Saddle Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (10)

DistanceCodeObservation
0MWM
159.3TSA
7.6TBA
5.3DAGS
0MWL
0AMH05 1749
382.9AMH05 1748
2DAGS
82.8TF
380DAGS

Properties (7)

additional_info
630074030121201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2021-03-02T01:03:58-08:00
documentation
PROPIPE
is_lateral_inspection
false