Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 19, 2021, 08:44 AM
  • 17 0006_17 0005_4192021_015042.mp4

Date
04/19/2021
W/O
0885989
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00668
PipeID
P13731
Time
1:44 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1777
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
03
Purpose
Maintenance Related
Project
20210413MDM_DISTRICT_17_MAIN_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
17 0006
Downstream MH
17 0005
Dir. of Survey
Downstream
Length Surveyed
317.9 ft.
Total Length
317.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1300
O&M Rating
3
Overall Index
1
Overall Quick
Overall Rating
3
Pipe schematic from manhole 17 0006 to 17 0005
MH: 17 0006MH: 17 0005downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. MWL - Water Level, 20 %of cross sectional area1 ft. MGO - General Observation - SEVER SHELF DAMAGE IN MH87.8 ft. RFC - Roots Fine Connection, from 09 to 11 o'clock, within 8 inches of joint: YES - 2%189.6 ft. RFC - Roots Fine Connection, from 02 to 04 o'clock, within 8 inches of joint: YES - 2%250.2 ft. RFJ - Roots Fine Joint, from 09 to 11 o'clock, within 8 inches of joint: YESR - 2%317.9 ft. AMH - Downstream Manhole, Survey Ends - 2:05AM

Observation photos (1)

  • General Observation - SEVER SHELF DAMAGE IN MH

    1 ft. - General Observation - SEVER SHELF DAMAGE IN MH

Observations (9)

DistanceCodeObservation
250.2RFJ2%
1MGOSEVER SHELF DAMAGE IN MH
0MWM
87.8RFC2%
0AMH1:45AM
317.9AMH2:05AM
0MGOConn. @ Mh, 9 O' Clock. OPEN
189.6RFC2%
0MWL

Properties (5)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2021-04-19T01:44:55-07:00
documentation
MARTIN,CASTILLO,RUVALCABA
is_lateral_inspection
false