Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2021, 09:16 AM
  • C 0564_C 0563_03112021_024654.mp4

Date
03/11/2021
W/O
880633
Weather
Heavy Rain
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00362
PipeID
P04748
Time
1:16 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8659
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
WO_880633_TV03080_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
10 in.
Upstream MH
C 0564
Downstream MH
C 0563
Dir. of Survey
Downstream
Length Surveyed
384 ft.
Total Length
384 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
11
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
19
Pipe schematic from manhole C 0564 to C 0563
MH: C 0564MH: C 0563downstream0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 05643 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start8.5 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.5 ft. MGO - General Observation - STEAM IN SEWER40 ft. MGO - General Observation - MISC. STAINING74.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start81.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish176.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start180.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish215.5 ft. CS - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start234.4 ft. CS - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish234.4 ft. FM - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES382.2 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish382.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish384 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK384 ft. AMH - Downstream Manhole, Survey Ends - C 0563

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • General Observation - MISC. STAINING

    40 ft. - General Observation - MISC. STAINING

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    74.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    176.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    215.5 ft. - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

    234.4 ft. - Fracture Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
215.5CS
0MWM
382.2DSC
3DAGS
234.4CS
74.4FL
8.5DSC
384MGOCONNECTION AT MH 3 O'CLOCK
8.5MGOSTEAM IN SEWER
180.9CL
0MWL
176.1CL
234.4FM
81.5FL
382.2DAGS
40MGOMISC. STAINING
384AMHC 0563
0AMHC 0564

Properties (7)

additional_info
630138031021231
custom_field_three
FRACTURES, CRACKS
custom_field_two
2
customer
1
datetime
2021-03-11T01:16:22-08:00
documentation
PROPIPE
is_lateral_inspection
false