Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2021, 10:33 AM
  • C 0561_C 0560_03112021_035059.mp4

Date
03/11/2021
W/O
880633
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00362
PipeID
P04745
Time
2:33 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8659
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
12
Purpose
Routine Assessment
Project
WO_880633_TV03080_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
21 in.
Upstream MH
C 0561
Downstream MH
C 0560
Dir. of Survey
Downstream
Length Surveyed
399.5 ft.
Total Length
399.5 ft.
Structural Index
3
Structural Quick
4132
Structural Rating
10
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
14
Pipe schematic from manhole C 0561 to C 0560
MH: C 0561MH: C 0560downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 05610 ft. MWL - Water Level, 20 %of cross sectional area2.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES32.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start74.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish106.9 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start289.8 ft. FS - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES363.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start397.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish397.9 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish399.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK399.5 ft. AMH - Downstream Manhole, Survey Ends - C 0560

Observation photos (3)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    2.9 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

    289.8 ft. - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    363.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWM
363.7DAGS
397.9DAGS
106.9DSC
399.5MGOCONNECTION AT MH 9 O'CLOCK
0AMHC 0561
289.8FS
0MWL
74.5FL
397.9DSC
2.9FM
32.7FL
399.5AMHC 0560

Properties (7)

additional_info
630138031021231
custom_field_three
FRACTURES
custom_field_two
2
customer
1
datetime
2021-03-11T02:33:18-08:00
documentation
PROPIPE
is_lateral_inspection
false