C 0558_C 0557_03112021_053915.mp4
3 ft. - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
7.5 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES
10.9 ft. - Fracture Multiple, from 11 to 12 o'clock, within 8 inches of joint: YES
14.4 ft. - Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES
34.1 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES
37.6 ft. - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES
41.3 ft. - Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES
45.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start
83 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES
136.5 ft. - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
149.3 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES
264.4 ft. - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES
268 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES
347.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES
369.8 ft. - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES
389.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 56.1 | DAGS | — |
| 393 | AMH | C 0557 |
| 389.4 | CM | — |
| 3 | MGO | STEAM IN SEWER |
| 3 | MGO | STAINING |
| 393 | MGO | CONNECTION AT MH 9 O'CLOCK |
| 149.3 | FS | — |
| 41.3 | CS | — |
| 32.2 | FS | — |
| 393 | DAGS | — |
| 34.1 | FM | — |
| 393 | MGO | CONNECTION AT MH 3 O'CLOCK |
| 37.6 | FM | — |
| 347.8 | FM | — |
| 0 | MWL | — |
| 0 | AMH | C 0558 |
| 369.8 | FS | — |
| 83 | RFJ | — |
| 148 | CS | — |
| 7.5 | CS | — |
| 45.1 | FL | — |
| 136.5 | CS | — |
| 14.4 | FM | — |
| 56.1 | FL | — |
| 3 | FS | — |
| 264.4 | CM | — |
| 0 | MWM | — |
| 268 | FS | — |
| 10.9 | FM | — |