Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 4, 2021, 10:57 AM
  • D 0161_D 0160_03042021_051616.mp4

Date
03/04/2021
W/O
880632
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00157
PipeID
P10037
Time
2:57 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8495
Sewer Name
D JOINT OUTFALL D - UNIT 6 RELIEF
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_880632_TV05173_MAR2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
27 in.
Upstream MH
D 0161
Downstream MH
D 0160
Dir. of Survey
Downstream
Length Surveyed
324.7 ft.
Total Length
324.7 ft.
Structural Index
4
Structural Quick
5L3L
Structural Rating
512
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
512
Pipe schematic from manhole D 0161 to D 0160
MH: D 0161MH: D 0160downstream0 ft. AMH - Upstream Manhole, Survey Begins - D 01610 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area3.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.8 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start321.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish322.3 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish324.6 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK324.7 ft. AMH - Downstream Manhole, Survey Ends - D 0160

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
324.7AMHD 0160
0AMHD 0161
3.5SAP
0MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
324.6MGOCONNECTION AT THE MH 9 OC'LOCK
322.3SRV
321.2SAP
0MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
4.8SRV
0MWL

Properties (8)

additional_info
630074030321202
custom_field_three
AGGREGATE PROJECTING/REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2021-03-04T02:57:16-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
29986