Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2021, 06:29 AM
  • 05 0702_05 0701_03172021_234542.mp4

Date
03/17/2021
W/O
880298
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00523
PipeID
P05934
Time
11:29 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8705
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_880298_TV05208_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
10 in.
Upstream MH
05 0702
Downstream MH
05 0701
Dir. of Survey
Downstream
Length Surveyed
264.7 ft.
Total Length
264.7 ft.
Structural Index
2
Structural Quick
5143
Structural Rating
376
O&M Index
2
O&M Quick
2J1E
O&M Rating
136
Overall Index
2
Overall Quick
Overall Rating
512
Pipe schematic from manhole 05 0702 to 05 0701
MH: 05 0702MH: 05 0701downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 07022 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start21.2 ft. RFJ - Roots Fine Joint, from 12 to 01 o'clock, within 8 inches of joint: YES31.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN35.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: NO38.7 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start83.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN117.3 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YES122.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start129 ft. B - Broken, from 07 to 04 o'clock, within 8 inches of joint: YES129 ft. FM - Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES130.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN161 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start174 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish179.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES181 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OP[EN223.8 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES231.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE262 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish262 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish264.7 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish264.7 ft. AMH - Downstream Manhole, Survey Ends - 05 0701264.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish264.7 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Water Level, Sag in pipe, 10 %of cross sectional area, Start

    38.7 ft. - Water Level, Sag in pipe, 10 %of cross sectional area, Start

  • Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

    129 ft. - Fracture Multiple, from 07 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    179.8 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    223.8 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

Observations (28)

DistanceCodeObservation
129B
21.2RFJ
264.7MWLS
181TFOP[EN
83.1TFOPEN
223.8FM
262DAGS
231.4TFACTIVE
262SSS
264.7AMH05 0701
264.7CM
2SSS
174MWLS
161MWLS
117.3RFJ
122.8RFJ
0MWL
0MWM
2DAGS
0AMH05 0702
130.2TFOPEN
264.7RFJ
31.9TFOPEN
179.8FM
129FM
35.2DAGS
38.7MWLS
2CM

Properties (7)

additional_info
630074031721202
custom_field_three
MULTIPLE CRACKS/FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-03-17T23:29:00-07:00
documentation
PROPIPE
is_lateral_inspection
false