Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 18, 2021, 06:56 AM
  • 05 0700_05 0699_03182021_001407.mp4

Date
03/17/2021
W/O
880298
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00523
PipeID
P05932
Time
11:56 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8705
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK, EXTENSION #2
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_880298_TV05208_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
10 in.
Upstream MH
05 0700
Downstream MH
05 0699
Dir. of Survey
Downstream
Length Surveyed
261.9 ft.
Total Length
261.9 ft.
Structural Index
3
Structural Quick
3J23
Structural Rating
166
O&M Index
2
O&M Quick
2311
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
173
Pipe schematic from manhole 05 0700 to 05 0699
MH: 05 0700MH: 05 0699downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 07000 ft. MWM - Water Mark, 25 %of cross sectional area1.7 ft. CC - Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.4 ft. RFJ - Roots Fine Joint, from 12 to 01 o'clock, within 8 inches of joint: YES24.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: YES51.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN99.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"101 ft. TBB - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6"101 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES102.9 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN151 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"200.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"249 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"259 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish259 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish261.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish261.9 ft. AMH - Downstream Manhole, Survey Ends - 05 0699

Observation photos (5)

  • Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES

    1.7 ft. - Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    101 ft. - Tap Break-In Abandoned, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    101 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    102.9 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

Observations (21)

DistanceCodeObservation
2SSS
249TFC
200.9TFC
1.7CC
259SSS
261.9CM
7.4RFJ
102.9TBOPEN
259DAGS
0MWL
0AMH05 0700
2DAGS
101TBB
261.9AMH05 0699
99.4TFC
151TFC
24.7DAGS
0MWM
101FL
2CM
51.6TFOPEN

Properties (7)

additional_info
630074031721202
custom_field_three
MULTIPLE CRACKS/FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-03-17T23:56:15-07:00
documentation
PROPIPE
is_lateral_inspection
false