Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 8, 2021, 09:40 AM
  • 05 0640_05 0126_02082021_015556.mp4

Date
02/08/2021
W/O
870427
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00520
PipeID
P05865
Time
1:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8468
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_870427_TV05343_JAN2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
10 in.
Upstream MH
05 0640
Downstream MH
05 0126
Dir. of Survey
Downstream
Length Surveyed
169.4 ft.
Total Length
169.4 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
117
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
117
Pipe schematic from manhole 05 0640 to 05 0126
MH: 05 0640MH: 05 0126downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - 05 06402 ft. MGO - General Observation - GREASE THROUGHOUT LINE4.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start68.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"71.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"74.2 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"135.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start165.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish167.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish169.4 ft. AMH - Downstream Manhole, Survey Ends - 05 0126169.4 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 3 OC'LOCK

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    74.2 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    135.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
68.7TFC
165.8FL
4.4CM
0MWM
135.4FL
0MWL
2MGOGREASE THROUGHOUT LINE
0MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
169.4AMH05 0126
0MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
169.4MGOACTIVE CONNECTION AT THE MH 3 OC'LOCK
167.5CM
74.2TB
71.7TFC
0AMH05 0640

Properties (7)

additional_info
630074020821001
custom_field_three
MULTIPLE CRACKS-FRACTURE'S
custom_field_two
3
customer
1
datetime
2021-02-08T01:40:40-08:00
documentation
PROPIPE
is_lateral_inspection
false