Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2021, 06:06 AM
  • 05 1603_05 1602_03082021_231513.mp4

Date
03/08/2021
W/O
880272
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00551
PipeID
P06827
Time
10:06 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8496
Sewer Name
05 203RD STREET TRUNK
City
TORRANCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
27
Purpose
Routine Assessment
Project
RFIR_WO_880272_TV05176_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Square
Height
24 in.
Width
15 in.
Upstream MH
05 1603
Downstream MH
05 1602
Dir. of Survey
Downstream
Length Surveyed
288.9 ft.
Total Length
288.9 ft.
Structural Index
4
Structural Quick
4N3J
Structural Rating
475
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
479
Pipe schematic from manhole 05 1603 to 05 1602
MH: 05 1603MH: 05 1602downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 16030 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CH2 - Crack Longitudinal Hinge, 2, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.1 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start50 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN100.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN139 ft. CH2 - Crack Longitudinal Hinge, 2, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish151.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN206.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN246.5 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish261.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN286 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish286 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish288.9 ft. AMH - Downstream Manhole, Survey Ends - 05 1602

Observation photos (1)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
151.7TFOPEN
2DAGS
288.9AMH05 1602
100.9TFOPEN
50TFOPEN
139CH2
2CM
0MWL
2CH2
286DAGS
206.7TFOPEN
286CM
261.7TFOPEN
0AMH05 1603
3.1FM
246.5FM
0MWM

Properties (7)

additional_info
630074030821201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
3
customer
1
datetime
2021-03-08T22:06:29-08:00
documentation
PROPIPE
is_lateral_inspection
false