- Date
- 03/03/2021
- W/O
- 875111
- Weather
- Heavy Rain
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00323
- PipeID
- P08160
- Time
- 12:21 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8651
- Sewer Name
- A JOA-1A LOS COYOTES WRP INTERCEPTOR
- City
- BELL GARDENS
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 26
- Purpose
- Routine Assessment
- Project
- RFIR_WO_875111_TV30023_FEB2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 60 in.
- Width
- 39 in.
- Upstream MH
- A 0438
- Downstream MH
- A 0437
- Dir. of Survey
- Downstream
- Length Surveyed
- 718.1 ft.
- Total Length
- 718.1 ft.
- Structural Index
- 2
- Structural Quick
- 3\2\
- Structural Rating
- 856
- O&M Index
- 2
- O&M Quick
- 2\1B
- O&M Rating
- 301
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 1157
Pipe schematic from manhole A 0438 to A 0437 Observation photos (2)

9.6 ft. - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

141.8 ft. - Alignment Right, 10 %, Start