Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 24, 2021, 08:04 PM
  • A 0154_A 0153_02242021_134443.mp4

Date
02/24/2021
W/O
875111
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00323
PipeID
P08091
Time
12:04 PM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8526
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
BELLFLOWER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_875111_TV30023_FEB2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
78 in.
Width
48 in.
Upstream MH
A 0154
Downstream MH
A 0153
Dir. of Survey
Downstream
Length Surveyed
758.9 ft.
Total Length
758.9 ft.
Structural Index
3
Structural Quick
5]3]
Structural Rating
1510
O&M Index
2
O&M Quick
2]00
O&M Rating
302
Overall Index
3
Overall Quick
Overall Rating
1812
Pipe schematic from manhole A 0154 to A 0153
MH: A 0154MH: A 0153downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 01542 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 75% MAG COAT2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start756 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish756 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish756 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish756 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish758.9 ft. MSA - Survey Abandoned - DUE TO TRACTION

Observations (13)

DistanceCodeObservation
0MWL
0MWM
0AMHA 0154
2SSS
756DAGS
756SSS
2DAGS
2MGO75% MAG COAT
756SAP
756SRV
2SAP
2SRV
758.9MSADUE TO TRACTION

Properties (8)

additional_info
630138022421061
custom_field_three
LIGHT GREASE
custom_field_two
5
customer
1
datetime
2021-02-24T12:04:27-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27936