Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2021, 07:01 PM
  • A 0149_A 0148_02262021_112150.mp4

Date
02/26/2021
W/O
875111
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00323
PipeID
P08086
Time
11:01 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8527
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
CERRITOS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
RFIR_WO_875111_TV30023_FEB2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
66 in.
Width
42 in.
Upstream MH
A 0149
Downstream MH
A 0148
Dir. of Survey
Downstream
Length Surveyed
459.8 ft.
Total Length
459.8 ft.
Structural Index
3
Structural Quick
513^
Structural Rating
646
O&M Index
2
O&M Quick
2Q00
O&M Rating
182
Overall Index
2
Overall Quick
Overall Rating
828
Pipe schematic from manhole A 0149 to A 0148
MH: A 0149MH: A 0148downstream0 ft. AMH - Upstream Manhole, Survey Begins - A 01490 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 70% MAG COAT2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start15 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 12" - OPEN141.9 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO141.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start452.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish457 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish457 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish457 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish459.8 ft. AMH - Downstream Manhole, Survey Ends - A 0148

Observation photos (2)

  • General Observation - 70% MAG COAT

    2 ft. - General Observation - 70% MAG COAT

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO

    141.9 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO

Observations (15)

DistanceCodeObservation
2SSS
2MGO70% MAG COAT
0AMHA 0149
141.9SRV
2SAP
0MWL
2DAGS
457SAP
459.8AMHA 0148
457SSS
15TBOPEN
141.9SAV
452.2SAV
0MWM
457DAGS

Properties (8)

additional_info
630138022621061
custom_field_three
REINFORSEMENT VISIBLE/AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2021-02-26T11:01:24-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27936