Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 26, 2021, 06:03 PM
  • A 0146_A 0927_02262021_101448.mp4

Date
02/26/2021
W/O
875111
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00323
PipeID
P08083
Time
10:03 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8527
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
CERRITOS
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
RFIR_WO_875111_TV30023_FEB2021
Sewer Type
Gravity
Material
RGRCP
Shape
Circular
Height
81 in.
Width
42 in.
Upstream MH
A 0146
Downstream MH
A 0927
Dir. of Survey
Downstream
Length Surveyed
97.3 ft.
Total Length
97.3 ft.
Structural Index
3
Structural Quick
3C2C
Structural Rating
95
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
99
Pipe schematic from manhole A 0146 to A 0927
MH: A 0146MH: A 0927downstream0 ft. MWL - Water Level, 100 %of cross sectional area0 ft. MWM - Water Mark, 100 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - A 01462 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. MGO - General Observation - 30% MAG COAT95 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish95 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish97.3 ft. AMH - Downstream Manhole, Survey Ends - A 0927

Observation photos (1)

  • General Observation - 30% MAG COAT

    2 ft. - General Observation - 30% MAG COAT

Observations (9)

DistanceCodeObservation
2SAV
95SAV
0MWL
0MWM
2SSS
0AMHA 0146
2MGO30% MAG COAT
95SSS
97.3AMHA 0927

Properties (6)

additional_info
630138022621061
custom_field_two
3
customer
1
datetime
2021-02-26T10:03:05-08:00
documentation
PROPIPE
is_lateral_inspection
false