Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2021, 06:04 PM
  • 29 0342_29 0341_03012021_112255.mp4

Date
03/01/2021
W/O
880264
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z01017
PipeID
P24362
Time
10:04 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7847
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Capital Improvement Program Assesment
Project
RFIR_WO_880264_TV29105_MAR2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0341
Downstream MH
29 0342
Dir. of Survey
Upstream
Length Surveyed
162.3 ft.
Total Length
162.3 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 29 0341 to 29 0342
MH: 29 0341MH: 29 0342upstream0 ft. MGO - General Observation - END POINT OF D/S SURVEY0 ft. MSA - Survey Abandoned - REVERSAL COMPLETED31.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"36 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES72.1 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"89.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"93.8 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES95.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"144.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159.8 ft. MGO - General Observation - MISC. STAINING162.3 ft. MWL - Water Level, 5 %of cross sectional area162.3 ft. MGO - Reversal Inspection162.3 ft. MWM - Water Mark, 15 %of cross sectional area162.3 ft. AMH - Downstream Manhole, Survey Begins - 29 0341

Observation photos (2)

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    68.5 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    126.3 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
90.2TFA
0MWL
72.9TFC
68.5CM
126.3CM
66.7TF
0MGO
17.9TFC
162.3MGOEND POINT OF D/S SURVEY
130.6TFC
0MWM
2.5MGOMISC. STAINING
0AMH29 0341
162.3MSAREVERSAL COMPLETED

Properties (7)

additional_info
630138030121061
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2021-03-01T10:04:48-08:00
documentation
PROPIPE
is_lateral_inspection
false