- Date
- 03/08/2021
- W/O
- 880264
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z01017
- PipeID
- P24340
- Time
- 1:22 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8655
- Sewer Name
- 29 PACIFIC COAST HIGHWAY SEWER
- City
- SIGNAL HILL
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 29
- Page No.
- 04
- Purpose
- Capital Improvement Program Assesment
- Project
- RFIR_WO_880264_TV29105_MAR2021
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 29 0345
- Downstream MH
- 29 0322
- Dir. of Survey
- Downstream
- Length Surveyed
- 476.2 ft.
- Total Length
- 476.2 ft.
- Structural Index
- 3
- Structural Quick
- 5131
- Structural Rating
- 12
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 12
Pipe schematic from manhole 29 0345 to 29 0322 Observation photos (3)

2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

448 ft. - Water Level, Sag in pipe, 10 %of cross sectional area, Start

468.7 ft. - Broken, from 08 to 12 o'clock, within 8 inches of joint: YES