Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 19, 2021, 09:59 AM
  • 29 0201_29 0180_02192021_022051.mp4

Date
02/19/2021
W/O
875678
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01025
PipeID
P24100
Time
1:59 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8612
Sewer Name
29 28TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Capital Improvement Program Assesment
Project
RFIR_WO_875678_TV29101_FEB2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0201
Downstream MH
29 0180
Dir. of Survey
Downstream
Length Surveyed
336.2 ft.
Total Length
336.2 ft.
Structural Index
3
Structural Quick
4133
Structural Rating
15
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole 29 0201 to 29 0180
MH: 29 0201MH: 29 0180downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 02017 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"9.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 8"28.3 ft. CM - Crack Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES53.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"57 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 8"58.1 ft. FM - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES74.4 ft. CS - Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES106.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"107.8 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES109.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"157.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"159.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 8"206.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"208.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"258.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"261.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"308.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"311.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"332.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES336.2 ft. AMH - Downstream Manhole, Survey Ends - 29 0180

Observation photos (6)

  • Crack Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

    28.3 ft. - Crack Multiple, from 09 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    58.1 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

    74.4 ft. - Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    107.8 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 8"

    159.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 8"

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    332.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
159.1TB
308.1TFC
206.5TFC
74.4CS
58.1FM
258.7TFC
336.2AMH29 0180
208.6TFC
9.8TFA
0MWL
332.7CM
28.3CM
157.1TFC
106.6TFC
0MWM
53.4TFC
57TF
107.8CM
109.5TFC
261.7TFC
7TFC
0AMH29 0201
311.1TFC

Properties (6)

custom_field_three
CRACKS, FRACTURES
custom_field_two
3
customer
1
datetime
2021-02-19T01:59:29-08:00
documentation
PRO PIPE
is_lateral_inspection
false