Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 12, 2021, 10:10 AM
  • 18 0039_18 0038_4122021_031052.mp4

Date
04/12/2021
W/O
0885736
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00689
PipeID
P13854
Time
3:10 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1774
Sewer Name
18 MILLS AVENUE TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Capital Improvement Program Assesment
Project
20210412MDM_MILLS_AVENUE_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
18 0039
Downstream MH
18 0038
Dir. of Survey
Downstream
Length Surveyed
370.7 ft.
Total Length
370.7 ft.
Structural Index
4
Structural Quick
4321
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole 18 0039 to 18 0038
MH: 18 0039MH: 18 0038downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:30AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG8 ft. MGO - General Observation - MAG COAT 90% START30.8 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG43.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Open44.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED89.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped94.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped150.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped156.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped203 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES204 ft. MGP - General Photograph - MISSING SEVERE AGG210.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped269.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open278.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped370.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active370.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG MISSING370.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN370.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRET SEVERE AGG ATTACHED370.7 ft. AMH - Downstream Manhole, Survey Ends - 4:05AM

Observation photos (6)

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 90% START

    8 ft. - General Observation - MAG COAT 90% START

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

    30.8 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

    44.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES

    203 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES

  • General Photograph - MISSING SEVERE AGG

    204 ft. - General Photograph - MISSING SEVERE AGG

Observations (22)

DistanceCodeObservation
89.1TFCCapped
370.2MGOConn. @ Mh, 9 O' Clock. Active
8MGOMAG COAT 90% START
269.2TFOpen
204MGPMISSING SEVERE AGG
278.2TFCCapped
0AMH3:30AM
370.2SAMSEVERE AGG MISSING
370.2MGOConn. @ Mh, 3 O' Clock. OPEN
370.2SSSPEELING CONCRET SEVERE AGG ATTACHED
203SAM
370.7AMH4:05AM
150.2TFCCapped
210.6TFCCapped
30.8SAMSEVERE AGG
2SAMSEVERE AGG
44.8SSSPEELING CONCRETE SEVERE AGG ATTACHED
0MWM
0MWL
156.2TFCapped
43.3TFOpen
94.9TFCCapped

Properties (6)

custom_field_three
PEELING CONCRETE SEVERE AGG ATTACHED
custom_field_two
2
customer
LACSD
datetime
2021-04-12T03:10:38-07:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false