Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2021, 06:29 AM
  • H 1285_H 1284_02102021_224720.mp4

Date
02/10/2021
W/O
870408
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01183
PipeID
P17301
Time
10:29 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8601
Sewer Name
H JOINT OUTFALL H - UNIT 8L
City
AZUSA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_870408_TV22154_JAN2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
H 1285
Downstream MH
H 1284
Dir. of Survey
Downstream
Length Surveyed
317.5 ft.
Total Length
317.5 ft.
Structural Index
2
Structural Quick
512K
Structural Rating
129
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
129
Pipe schematic from manhole H 1285 to H 1284
MH: H 1285MH: H 1284downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 12850 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK4 ft. MGO - General Observation - MAG COAT4.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 8"50.5 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES60.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 8"65.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"68.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"116.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"125.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"173.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"181.2 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"221.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"229.4 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"277.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"285.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"314.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317.5 ft. AMH - Downstream Manhole, Survey Ends - H 1284

Observation photos (7)

  • General Observation - MAG COAT

    4 ft. - General Observation - MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

    50.5 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

    65.5 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

    125.5 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

    181.2 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

    229.4 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

Observations (21)

DistanceCodeObservation
277.9TFC
4.2SSS
116.9TFC
0AMHH 1285
221.7TFC
125.5TB
229.4TB
285.9TFC
0MWM
181.2TB
0MWL
317.5AMHH 1284
12TFC
314.8SSS
4MGOMAG COAT
173.5TFC
50.5SRV
60.6TFC
65.5TB
68.9TFC
0MGOCONNECTION AT MH, 3 O'CLOCK

Properties (6)

custom_field_three
SPALLING, MAG COAT, REINFORCEMENT VISIBLE
custom_field_two
2
customer
1
datetime
2021-02-10T22:29:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false